High Temperature Compensation Wire

高溫補償導線.jpg
  • 高溫補償導線.jpg
High temperature compensation wire is suitable for temperature control system of energy, metallurgy,…

Description:

A brief introduction, conductor:
Temperature compensation wireThe effect is to extend the thermode that cold end of thermocouple temperature measurement system and mobile display instrument is connected.High temperature thermocouple compensation wire insulation layer and protective layer according to the environmental requirements of the selected material is not the same, PVC sheath material, fluorine plastic, low smoke and low halogen PVC and alkali free glass wire several imported high-quality fluorocarbon can be high temperature of 260 DEG C, and the continuous extrusion process, make the product has excellent acid resistance, alkali resistance, and flame extension performance, can be used for a long time in oil.
Temperature compensation wireThe use of temperature in - 60 - 260 C, which belongs to the contemporary domestic advanced level.Series of products are mainly used in various types of temperature measuring device, according to the variety of products is divided into SC, KC, KX, EX, JX, TX, NC.
Two, the implementation of standards: GB/T4989/94 equivalent to IEC584.3,
Three, use range:
Temperature compensation wireApplicable to energy, metallurgy, petroleum, chemical and other industrial enterprises and scientific research departments, the temperature control system.For the connection between the cold end temperature measuring instrument and temperature measuring instrument.Heat type imported fluorine plastic insulated and sheathed with excellent heat resistance, waterproof, anti-corrosion, anti acid, chemical resistance, resistance to abrasion, aging and combustion performance.Use temperature of -60 to 260 DEG C, is the international advanced level.
Three, the conditions of use:
(1): highest working temperature: heat with 200 degrees and 260 degrees two;
General: a maximum of 70 degrees and 105 degrees two.
(2) the lowest ambient temperature: fluorine plastic insulated and sheathed cable laying: -60 C -20 C non fixed installation;
PVC insulated and sheathed cable laying: -40 C -15 C non fixed installation.
(3) the minimum bending radius: PVC insulated and sheathed cable non armored cable is not less than 6 times of cable diameter, 10 times of fluoroplastic insulation and sheath for non armored cable is not less than the diameter of the cable, not less than 12 times of cable diameter for armored cable.
Four,Temperature compensation wireThe use of characteristics:

type

The minimum bending radius

The lowest temperature

Maximum temperature

Unarmored

Armoured

Fixed installation

Non fixed installation

General type
There are 105 types of ""
There are 90 types of ""
High temperature type

6 times of the cable diameter
10 times of the cable diameter

12 times of the cable diameter

C = -40

C = -60
 

C = -15

C = -20
 

Less than or equal to 70 DEG C
Less than or equal to 105 DEG C
Less than or equal to 90 DEG C
Less than or equal to 250 DEG C

Five, product code and meaning:

project

Code

Code meaning

project

Code

Code meaning

Model

SC

Thermocouple compensation wire, S index

Heat resistant grade

Seventy

The highest temperature is 70 DEG C

RC

Thermocouple compensation wire, R index

One hundred and five

The highest temperature is 105 DEG C

NC

Thermocouple compensation wire, N index

Two hundred

The highest temperature is 200 DEG C

NX

Thermocouple compensation wire, N index

Two hundred and fifty

The highest temperature is 250 DEG C

KCA
KCB

Thermocouple compensation wire, K index

Insulating materials

V

polyvinyl chloride

KX

Thermocouple compensation wire, K index

Y

polyethylene

EX

Thermocouple compensation wire, E index

B

polypropylene

JX

Thermocouple compensation wire, J index

F4

Teflon

T

Thermocouple compensation wire, T index

F46

Poly perchloro ethylene propylene

Series code

ZR

Flame retardant cable

Jacket material

V

polyvinyl chloride

IA

Intrinsically safe cable

B

glass fibre

The use of classification

G

For general use

F4

Teflon

H

heat resistant

F46

Poly perchloro ethylene propylene

Precision grade

S

Precision

Shielding material

P

Copper wire braid

P1

Tinned copper braid

/

Common grade

P2

Copper tape wrapped

P3

Aluminum / plastic composite film wrapping

Specifications


2 x conductor cross-sectional area mm2

Conductor type


Single conductor can be omitted

R

Stranded conductors

Armored

Twenty-two

Steel tape

Thirty-two

Steel wire armoured

Six, technical indicators:
1 type alloy wire material and insulation color

Compensation wire type

Thermocouple

Mark thermocouple

Compensation lead wire

The insulation layer of color

Positive order

The negative

Positive order

The negative

SC

10- Platinum Rhodium Platinum thermocouple

S

SPC (copper)

SNC (Cu, Ni)

red

green

RC

13- platinum rhodium thermocouple

R

RPC (copper)

RNC (Cu, Ni)

red

green

KCA

Nickel chromium nickel silicon thermocouple

K

KPCA (iron)

KNCA (Cu, Ni)

red

blue

KCB

KPCB (copper)

KNCB (Cu, Ni)

red

blue

KX

KPX (CR)

KNX (Ni SI)

red

black

NC

Ni Cr Si Ni Si thermocouple

N

NPC (iron)

NNC (Cu, Ni)

red

ash

NX

NPX (Ni Cr SI)

NNX (Ni SI)

red

ash

EX

Nickel - copper nickel thermocouple

E

EPX (CR)

ENX (Cu, Ni)

red

Brown

JX

The iron - copper nickel thermocouple

J

JPX (iron)

JNX (Cu, Ni)

red

purple

TX

Copper - copper nickel thermocouple

T

TPX (copper)

TNX (Cu, Ni)

red

white

2, the use of protective layer of color classification

The use of classification

Precision grade and sign

Jacket color

Common grade

Precision

Common grade

Precision

For general use

G

/

S

black

gray

heat resistant

H

/

S

black

yellow

Seven, delivery requirements:
According to both agreements, the length of measurement error is about 0.5%.
Eight, ordering:
In order to indicate the product name, type, number, temperature rating, shielding type, quantity etc..


Browse:
Return To The Top

分享到:

主站蜘蛛池模板: 成人三级k8经典网 | 日本护士浽乱理片无码 | 91久9在线 | 传媒 | 亚洲美女激情视频 | 思思热国产| 日韩精品高清自在线 | 福利姬液液酱喷水 | 一级做a爱片毛片免费 | 91全国免费视频精品 | 欧美一級交配視頻 | 91是什么 | 久久人妻久久 | 国产免费乱理伦片在线观看 | 国产簧片免费观看 | 三级日本午夜在线观看 | 精品婷婷伊人 | 国产乱伦视频网 | 色情乱婬A片无码专区网站直播 | 粉嫩小泬久久久一区二区 | 人人玩人人添人人澡免费 | 91精品国产一区二区 | 日本一本道视频 | 99热这里只有精品66 | 91看片免费 | 视频福利在线 | 成人视频在线观看夜晚模式 | 亚洲成人无码A V原创区 | 五月综合激情 | 成人免费无码区色情免费 | 国产精品一区二区三区四区五区上线网友表示 | 精品一区二区三区三区 | 欧美高清国产一区二区三区 | 无码一级毛片一区二区视频孕妇 | 麻豆一区在线观看视频一区 | 综合五月婷婷 | 九九综合九色综合欧美狠狠 | 色中色成人网址 | 99尹人香蕉国 | 乱伦片中文字幕 | 欧美成AAA人片在线观看蜜臀 | 成人亚洲无码一区 |