Rosemount 3051L Flanged Installed Level Transmitter

羅斯蒙特3051L法蘭安裝液位變送器.jpg
  • 羅斯蒙特3051L法蘭安裝液位變送器.jpg
Ross Monte 3051L flange mounted liquid level transmitter Due to the adoption of ASIC amplifier desig…

Description:

Productoverview:
Ross Monte 3051L flange mounted liquid level transmitter Due to the adoption of ASIC amplifier design to make the packaging becomes small, and the miniaturization of the membrane structure and the flange of the box, this type of weight dropped to half of the original type. ASIC design not only reduces the number of parts, but also improve the reliability of the amplifier.
Two, work principle:
When working, the high and low pressure side of the diaphragm and the filled liquid transmit the process pressure to the filling liquid filled liquid, then transmits the pressure to the center of the sensing diaphragm sensor. The sensing membrane is a elastic element of tension, compression and displacement with the change (for GP gauge transmitter, atmospheric pressure as applied in the low voltage side of the sensing membrane.). The AP absolute pressure transmitter, low voltage side always maintain a reference pressure. The sensing membrane Zui large displacement is 0.004 inches (0.1 mm), and the displacement is proportional to pressure. The capacitor plates on both sides of the diaphragm position detection sensor. The difference between the capacitance sensing diaphragm and capacitor plate is converted to the corresponding voltage or current, HART (high speed digital data highway addressable remote transmitter output signal).
Third, widely used:
For the measurement of gas, liquid and vapor pressure, and then turn it into a current signal output 4-20mADC. Can HART375, 475 hand operator to communicate with each other, setting and monitoring through them.
Fourth, the main features:
1, 5 years of continuous work without adjustment;
2, the temperature effect is negligible;
Influence of static pressure can be ignored;
3, one-way impact: 100 thousand consecutive unidirectional overvoltage overvoltage after the experiment affect the amount of less than 0.03%;
4, improve the self diagnosis function;
5, small, lightweight (standard 3.9kg);
6, static effects are neglected:
When a static pressure (pressure), resonant beam deformation two shape, size and material identical to the same, so the frequency change is consistent, so the deviation automatically cleared (figure similar formula and temperature influence).
7, excellent properties of unidirectional overvoltage:
The liquid membrane and the membrane using corrugated box body processing technology of the original, so that the external pressure increases to a certain value, the film can fully contact with the body, silicone oil is transferred to the sensor pressure no longer increase with the increase of external force, so as to achieve the protective effect on sensor.
Five, technical parameters:
The 1. level measurement accuracy of 0.075%;
2. calibration range from 0.25inH2O to 8310inH2O;
3. flat film chip, 2-, 4-, and inch extend type diaphragm;
4. kinds of filling liquid optional, can meet the requirements of different applications;
5. clever and lightweight, easy installation and maintenance;
6. liquid material: 316L stainless steel, Hastelloy, tantalum.
Six, selection table:

Model

Product name

3051L

Flange mounted liquid level transmitter

Code

Pressure range (range /zui Small range)

Two

-250 to 250inH Two O/2.5H Two O (-62.2KPa to 62.2KPa/0.62KPa)

Three

-1000 to 1000inH Two O/10H Two O (-248KPa to 248KPa/2.5KPa)

Four

-8310 to 8310inH Two O/83.1H Two O (-2070KPa to 2070KPa/20.7KPa)

Code

output

A

4-20mA Based on a HART Digital signal protocol

M

Low power consumption, 1-5VDC Based on a HART Digital signal protocol ( 0.8-3.2VDC Output option code C2 )

F

FF Bus

W

PROFIBUS

Code

Diaphragm size

Material Science

Extended length

Notes

G0

2in./DN 50

316L SST

Only the plane type

Extension with diameterEighty The Conduit

Size. Of Forty Pipe size,

Please consult factory.

H0

2in./DN 50

Hastelloy C-276

Only the plane type

J0

2in./DN 50

tantalum

Only the plane type

A0

3in./DN 80

316L SST

Plane type

A2

3in./DN 80

316L SST

2in./50mm

A4

3in./DN 80

316L SST

4in./100mm

A6

3in./DN 80

316L SST

6in./150mm

B0

4in./DN 100

316L SST

Plane type

B2

4in./DN 100

316L SST

2in./50mm

B4

4in./DN 100

316L SST

4in./100mm

B6

4in./DN 100

316L SST

6in./150mm

C0

3in./DN 80

Hastelloy C-276

Plane type

C2

3in./DN 80

Hastelloy C-276

2in./50mm

C4

3in./DN 80

Hastelloy C-276

4in./100mm

C6

3in./DN 80

Hastelloy C-276

6in./150mm

D0

4in./DN 100

Hastelloy C-276

Plane type

D2

4in./DN 100

Hastelloy C-276

2in./50mm

D4

4in./DN 100

Hastelloy C-276

4in./100mm

D6

4in./DN 100

Hastelloy C-276

6in./150mm

E0

3in./DN 80

tantalum

Only the plane type

F0

4in./DN 100

tantalum

Only the plane type


Code

Installation flange size

Rating

Material Science

Applicable to high voltage side of diaphragm size

M

2in.

One hundred and fifty level

carbon steel

2 in./DN50

A

3in.

One hundred and fifty level

carbon steel

3 in./DN80

B

4in.

One hundred and fifty level

carbon steel

4 in./DN100

N

2in.

Three hundredlevel

carbon steel

2 in./DN50

C

3in.

Three hundredlevel

carbon steel

3 in./DN80

D

4in.

Three hundredlevel

carbon steel

4 in./DN100

P

2in

Six hundredlevel

carbon steel

2 in./DN50

E

3in.

Six hundredlevel

carbon steel

3 in./DN80

X

2in.

One hundred and fifty level

SST

2 in./DN50

F

3in.

One hundred and fifty level

SST

3 in./DN80

G

4in.

One hundred and fifty level

SST

4 in./DN100

Y

2in.

Three hundredlevel

SST

2 in./DN50

H

3in.

Three hundredlevel

SST

3 in./DN80

J

4in.

Three hundredlevel

SST

4 in./DN100

Z

2in.

Six hundredlevel

SST

2 in./DN50

L

3in.

Six hundredlevel

SST

3 in./DN80

Q

DN 50

PN 10-40

carbon steel

2 in./DN50

R

DN 80

PN 40

carbon steel

3 in./DN80

S

DN 100

PN 40

carbon steel

4 in./DN100

V

DN 100

PN 10/16

carbon steel

4 in./DN100

K

DN 50

PN 10-40

SST

2 in./DN50

T

DN 80

PN 40

SST

3 in./DN80

U

DN 100

PN 40

SST

4 in./DN100

W

DN 50

PN 10/16

SST

4 in./DN100


Code

The process of oil filling -High pressure side

Temperature limit

A

Syltherm XLT

-75 to One hundred and fifty C (-102 to302 ~ F)

C

D.C.704 silicone oil

Zero to Two hundred and five C (32 to401 degrees F)

D

D.C.200 silicone oil

-45 to Two hundred and five C (-49 to401 degrees F)

H

Inert liquid

-45 to One hundred and seventy-five C(-49 to 347 degrees F)

G

Glycerin and water

-15 to Ninety-five C (5 to 203 degrees F)

N

Neobee M-200

-15 to Two hundred and five C (5 to 401 degrees F)

P

Propylene glycol and water

-15 to Ninety-five C (5 to 203 degrees F)


Code

option


Header

M (1)

Linear meter, 0-100% scale

M3 (1)

The special calibration table, specify the range

M4 (1)

LCD Header, 0-100%

M7 (1)

LCD First, linear, special set


Hazardous area certification

E5

The Canadian Standards Association (CSA) Flameproof certification

I5 (2)

Factory mutual (FM) Non flammable and safety certification

K5

Factory mutual (FM) Flameproof and intrinsically safe comprehensive certification

C5 (3)

Canada certification industry and Science ( Only Canada )

C6 (2)

I6 and E6 Combination, CSA Flameproof and intrinsically safe certification


( Requirement Zui High power supply voltage 42.4Vdc)

K6

CSA/CENELEC Flameproof and intrinsically safe certification

EF (4)

China NEPSI, GB Flameproof certification standard

EF (2) (4)

China NEPSI, GB Standard essential safety certification

E4

Japanese industrial standard (JIS) Flameproof certification

E7

The Standards Association of Australia (SAA) Flameproof certification

E8

CESI/CENELEC Flameproof certification

I1 (2)

BASEEFA The essence of security authentication

I7 (2)

The Standards Association of Australia (SAA) The essence of security authentication

I8 (5)

CESI/CENELEC The essence of security authentication

N1 (2)

BASEEFA N Type certification

N7

The Standards Association of Australia (SAA) Non flammable safety certification

IC (2)

SEV The essence of security authentication


Other options

W5

copper O Ring type, used for vacuum occasions (non wetted parts)

Q4

Check data sheet

Q8 (6)

Material traceability, in accordance with EN 10204 3.1B

L4

316 SST Flange and bolt joints

V1

Inverting output

V2

4-20mV test signal

V3

20-100mV test signal

Z1 (7)

4- Line, 0-20mA output

Z2 (7)

4- Line, 0-16mA output

Z3 (7)

4- Line, 0-10mA output

F_

From table flush connection options in selecting a set of code

Seven typical models:

3051L2AG0RD21AAK5M5Q4
3051L2AH0KD21AAM5
3051L3AA0FD21AB



Browse:
Return To The Top

分享到:

主站蜘蛛池模板: 国产午夜人做人免费 | 东方伊甸园av在线 | 久久精品亚洲国产奇米99 | 国产最新中文字幕 | 少妇粉嫩小泬喷水 | 国产又粗又硬 | 日韩在线我不卡 | 免费一看一级欧美 | 成年女人毛片 | 国产午夜无码精品免费视频 | 91天堂在线视频 | 性欧美vidaofree| 国产欧美成人一区二区3D | 精品极品国产呦在线观看 | 亚洲色偷拍另类无码专区 | 理伦片在线观看日本一区二区 | 999精品免费视频观看 | 欧洲免费成人精品视频 | 最新热播韩剧电影免费在线观看 | 日屄视频免费在线播放 | 激情欧美一区二区 | 男人猛躁女人秘 91网站 | 国产偷抇久久久久 | 亚洲AV一三区 | 日本蝌蚪网 | 91喷水 | 艳情麻豆天美视频 | 日本女同中文字幕、 | 国产区日韩 | 深夜福利亚洲 | 国产在线导航 | 免费看A级 | 国产激情视频专区在线观看 | 国产精品无码午夜福利免费看 | 暗交拗女一区二区三区主演是谁 | 亚洲图片另类小说 | 在线观看日韩视频 | 日韩乱码在线观看 | 亚洲佬中文字幕在线免费观看视频 | 91精品国产高清自在线看香蕉网 | 成人在线视频亚洲区 |