Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.

Conventional type connecting rod ball float liquid level switch

25連桿浮球液位開關(普通型)03.png
25連桿浮球液位開關(普通型)01.png
25連桿浮球液位開關(普通型)02.png
  • 25連桿浮球液位開關(普通型)03.png
  • 25連桿浮球液位開關(普通型)01.png
  • 25連桿浮球液位開關(普通型)02.png
Ordinary connecting rod ball float liquid level switch is for the automatic alarm and control of all…

Description:

Products overview:

ZW - UQK seriesConventional type connecting rod ball float liquid level switchIn airtight metal, dry reed pipe set one or more points, and then through one or more of the hollow pipe and internal floating ball with ring magnet, using fixed ring will float fixed within the scope of the associated with the magnetic reed switch, when floating ball movement, its internal magnets attract magnetic reed switch contact action, as a liquid level control or instructions.The product by the isolation of a floating ball and micro switch group 2.

Second, the working principle:

ZW - UQK series type connecting rod ball float liquid level switch is based on the working principle of buoyancy, the liquid level down float float inside the magnet, float along with the change of liquid level fluctuation, through magnetic shaft drive, drive the micro switch contact action, realize the liquid level alarm or control.Reed switch with each intended to measure or alarm level is fixed, guide bar and float guiding role, move up and down float with the guide bar, reed switch is in a magnetic field on, in the outside magnetic field when a disconnected state.Detection of the dry reed pipe in the pipe under the influence of magnetic field and divide or close.Drive micro switch element action accordingly.

Three, the application occasion.

ZW - UQK series type connecting rod ball float liquid level switch is for the automatic alarm and control of all kinds of container level.It is widely used in petroleum, chemical, electric power, metallurgy, food, pharmaceutical, paper making industries.With self-monitoring ball float liquid level switch can be easily at any time to switch and the system self test, to ensure that the switch and the safe operation of the system.

Four, the main features:

1, advanced design and strict manufacturing technology to provide a reliable guarantee of product quality.

Case 2, ABS, PP, PVC plastic, high strength, good corrosion resistance.

3, cable with special materials, they can withstand oil, acid, alkali, corrosion resistance is superior.

4, simple structure, reliable in performance.Output is stable and reliable "tong" and "off" switch signal, without any wrong operation, high reliability.

5, easy installation, convenient debugging, move up and down positioning block, can adjust at liquid level control.

Five, the technical parameters:

1, the working temperature: standard: - 40 ~ 150 ℃;

Medium temperature type: - 40 ~ 250 ℃;

High temperature type: - 40 ~ 350 ℃;

2, environmental temperature: - 40 ~ 70 ℃;

3, working pressure: 0.1 ~ 6.3 MPa.

4, medium density: acuity 0.45 g/cm3.

5, the output signal: SPDT relay (single pole double throw);

6, contact capacity: 250 vac 7 a.

7, switch life: 5 x l04 times;

8, electrical interface: M20 thread in x 1.5;

9, explosion-proof grade: flameproof Exd Ⅱ BT4;

The Ann model Exia Ⅱ CT1 ~ T6.

10, protection level: IP65;

11, process connection: HG20592 ~ 20635-97 (above, other flange standards when ordering user, please indicate;

12, liquid material: stainless steel;

13, junction box material: aluminum alloy.

Six, installation instructions:

1, the installation position should be far away from the water inlet, otherwise will switch the misoperation caused by fluctuations in water inlet.

2, if the switch device in the vessel wall, L type Angle bracket can be mounted to the system.

3, if the switchgear in mixing zone, can be installed or wave wave tube platens.

4, choose pipe diameter greater than the float of the diameter of the flange connecting pipe.

More than 5, wiring advice use core cable.

6, the control circuit load must match the float switch contact capacity.

7, the proportion of liquid to be tested must be greater than the proportion of floating ball.

8, the action point floating ball is already in the factory according to customer orders to adjust, please don't adjust floating ball position.

Seven, contact protection circuit:

1, when the float switch used in motor, relay, solenoid coil of inductive load circuit, such as advice on both ends of the load in parallel circuit protection such as RC (buffer), resistor, diode, etc.

Note: do not use the float switch connected directly to the electromagnetic valve, the motor or electromagnetic switch

2, when the float switch used in capacitor, incandescent light bulbs, there is a long cable capacitive load, such as between switch contact will produce a surge current;Advice on both ends of float switch protection circuit in parallel, such as a current limiting resistor or surge absorber, etc.

Eight, wiring and contact details:

1, open the box, the cable from the line wear into the mouth, and lock into the line cable fixed head, according to the nameplate and patch panel terminals on the logo will be on contact wire connected to the corresponding terminal.

2, patch panel terminal stage identification Numbers from small to large from top to bottom corresponds to the floating ball contact.

3, the floating ball contacts are divided into three types:

1 1 A: said level higher than the float A - C contact through

(2) 1 B: it means the level below the float B - C contact through

(3) 1 ab: it means the level below the float A - C contact disconnect, B - C connected;Liquid level is higher than the float is A - C contact through, B - C disconnect

4, after the completion of the connection will be lifted the lid, please tighten and wiring fixed, in order to ensure waterproof connector.

Nine, common faults and eliminate:

1, the failure phenomenon, cause analysis and elimination method

Floating ball is not action

(1) the proportion of liquid is less than the proportion of floating ball - that the proportion of floating ball

(2) the floating ball is leaking and contact with the company change the floating ball

(3) foreign body removal stuck float -

2, floating ball movement, but no signal output

Floating ball position offset to adjust the floating ball position.

Ten, selection of code:

Factory standard

Registration type

Code instructions

ZW-

UQK80

In ordinary connecting rod ball float liquid level switch (wei measurement and control)

ZW-

UQKS80

Take self-inspection connecting rod ball float liquid level switch

Code name

Basic types of

S: stainless steel3044;316;The temperature: - 30~120℃;pressure:≤2.5Mp。

F: polypropylenePP ;The temperature: - 30~80℃;Pressure:Or less0.4Mpa

P: ptfePTFE ;The temperature: - 30~160℃;pressure:≤1.0Mpa

S

standard

F

Anti-corrosion type

P

The corrosion type

Code name

Process connection

A

The flangeDN50

B

The flangeDN80

C

The flangeDN100

D

External threadG2(The corrosion type, not with the specifications)

Code name

The control points

1

1A control switch,1A floating ball

2

2A control switch,2A floating ball

3

3A control switch,3A floating ball

4

4A control switch,4A floating ball

N

NA control switch,NA floating ball

Code name

Answer the liquid material

B

1Cr18Ni9Ti、321

S

304SS

L

316L

P

PP、PPR

F

PTFE

C

PVC

Code name

Optional item

D

flameproof ExdIICT2~T6

E

The Ann model ExizCT2~T6

C

With the converter (a convertible two control points)

F

With isolation security gate

Code name

The installation height

-

L1mm,Under the lower limit, fell through

-

L2mm,The lower limit,Fall through

-

L3mm,ceiling,Up through

-

L4mm,On the ceiling,Up through

-

LNmm,L connected or fall through

Code name

Medium density

-

(kg/m3)

Code name

The rated pressure

D

Atmospheric pressure

Note: please specify your connection mode, the process of the size and action point location.

Eleven, design selection and ordering information:

1, liquid level control device specifications;

2, measurement range;

3, working pressure, and temperature;

4, control device for material;

5, special requirements;

6, whether level device matching supply vessel flange, bolts, nuts, valves and fittings such as sealing washer, so that the correct selection.

After-sales service commitment:

Liquid level switch 1, I companies sell products within twelve months appear quality problem, is responsible for free maintenance.

2, the warranty period, any quality problems such as the products of our company, my company is responsible for free repair or replacement.

3, the warranty period, such as user improper use, damaged products, my company is responsible for the maintenance, charge damage parts cost.

4, after the warranty period appear quality problem, my company is responsible for the maintenance, charge damage parts cost.

5, such as user need to my company site services, to users in the province I company service personnel to reach the site within 12 hours, fujian association of foreign languages and user reach the site within 48 hours.

Browse:
Return To The Top

分享到:

主站蜘蛛池模板: 99自拍视频偷拍视频 | 国产91哺乳期挤奶真人 | 亚洲高清国产拍精品影院 | 成人精品一区二区三区免费视频 | 欧美乱伦第三页 | 无码精品人妻一区二区三区白浆 | 天天影视涩香欲 | 美女视频网站黄 | 亚洲高清AV在线 | 成人综合AV | 国产主播一区二区三区在线观看 | AV手机在线观看一区二区三区 | 福利岛视频二区xly 福利电影91 | 精品人妻无码潮喷 | 麻豆伦理影院 | 日本不卡在线 | 白嫩小脚玉足足交在线观看网站 | 日韩一区二区精品 | 日韩欧美一区国产精品 | 国产精品成人AV片 | 国产在线毛 | 我想看黄色录像3级片 | 男人的天堂2025 | 91香蕉直播 | 欧美黄页| 日韩在线不卡看 | 日日夜夜撸视频 | 日韩欧美卡一卡二卡新区 | 成人AV TV| 免费看男女做爰爽爽视频 | 日韩性爱视频在线观看 | 日韩免费a级二区三区 | 乱伦视频一区二区三区 | 99re欧美精品在线观看 | 久久久精品人妻一区二区蜜桃 | 精品国产亚洲一区二区在线3d | 囯产棈品久久久久久久久久久久 | 日韩成人中文字幕在线网站 | 国产白丝喷水在线 | 国产精品三级AV在线观看 | 日韩AV片在线观看 |