Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.

Anticorrosive static pressure type level gauge

23防腐靜壓式液位計.jpg
  • 23防腐靜壓式液位計.jpg
Anticorrosive static pressure type level gauge pressure sensor in Germany original component product…

Description:

Products overview:

ZW - DB403 seriesAnticorrosive static pressure type level gaugeIs a kind of measuring the pressure of liquid level sensor, USES the overseas advanced isolation diffusion silicon sensing element or sensitive ceramic capacitance pressure sensor, the static pressure is converted to electrical signals.Sensors and cables are ptfe material corrosion resistance is strong, is mainly used in petrochemical, mining, boiler, environmental protection, water conservancy and other industries, water, chemical solution, the depth of the pulp, such as the crude oil atmospheric liquid measurement.

Second, the working principle:

ZW series - DB403 anticorrosive static pressure type level gauge based on the measured liquid the principle of static pressure is proportional to the height of the liquid, the piezoresistive effect of diffused silicon or ceramic sensitive element, the static pressure into electrical signals.After temperature compensation and the linear correction.Converted into a standard 4-20 madc current signal output.When the liquid level transmitter into the liquid to be tested in a certain depth, the sensor to meet the pressure on liquid surface formula is: Ρ = rho. We + Po type:

P: the pressure on the transmitter into liquid level;

Rho: the measured liquid density;

G: the local acceleration of gravity;

Po: liquid surface atmospheric pressure;

H: transmitter into the depth of the liquid.

At the same time, through the gas leading stainless steel will be introduced to the liquid pressure sensor of positive pressure cavity, and atmospheric pressure on the surface of the liquid Po and sensors connected to the negative pressure cavity, to offset the Po on the reverse of the sensor, the sensor measured pressure is: rho. We, obviously, through the acquisition of pressure P, can get the depth of the liquid level.

Applications:

ZW series - DB403 anticorrosive static pressure type level gauge is suitable for the petroleum chemical industry, metallurgy, electric power, pharmaceutical, water supply and drainage, environmental protection system and industry such as all kinds of medium level measurement.Exquisite structure, simple adjustment and flexible installation convenience is provided for the user to easily use.4 ~ 20 ma, 0 ~ 5 v, 0 ~ 10 ma and standard signal output by the user choose according to need.

Four, the main features:

1, good stability, full, zero long-term stability can amount to 0.2% FS/year.Within the scope of the compensation temperature 0 ~ 70 ℃, the temperature drift less than 0.2% FS, throughout the allowed working temperature range is less than 0.5% FS.

2, with reverse protection, current limiting protection circuit, when the installation is negative answer the reverse will not damage the transmitter, exception to send automatically within 35 ma current limit.

3, solid structure, no moving parts, high reliability, long service life.

4, easy installation, simple structure, economy is durable.

Five, the technical parameters:

1, the measuring range: 0-0.1 m ~ 0 to 35 meters;

2, zui big overload: 1.5 times less than the tube length

3, survey forms: balanced bell type;

4, precision grade: 0.5% FS.

5, power supply voltage: 24 VDC;

6, load resistance: 500 Ω or less;

7, measuring medium: all kinds of liquid.

8, long-term stability: plus or minus 0.2% FS/year;

9, environment relative humidity: 0 ~ 95%;

10, compensation temperature: 0 ~ 70 ℃;

11, the working temperature: - 40 ~ 240 ℃ high temperature zui can do 350 degrees (order).

Six, the structure and materials:

1, transmitter relay box: cast aluminum, 100 x 68 x 110, shell epoxy resin coating;

2, transmitter probe: 1 crl8ni9ti, 30 x 150 29, anti-corrosion for 30 to 44 * 140;

3, guide gas cable: 30 diameter 7 6 core PVC cable, anti-corrosion cable sheath for ptfe;

4 (excluding gas leading cable), weight: 0.6 kg;

5, electrical interface: M20 x 1.5.

Seven, installation and debugging methods:

1, cable type and lever type liquid level transmitter has many installation fixed way, so as to adapt to different site conditions.When the site will not be able to provide M20 x 1.5 in the process facilities such as thread or the flange, can choose wall installation type, horizontal pipe frame and vertical posture, such as three optional installation way, make you comfortable when installation.

2, when measuring liquidity larger medium, to prevent violent oscillation sensor, the user can choose counterweight attachment, to have the effect of stable sensors, add weight must to put weight objects in the bottom of the container, in order to avoid pull bad sensing wires.

In the field environment is bad, the user should choose sensor shield to protect sensor, to avoid the foreign body damage or affect the accuracy of measurement.

3, when using the lever type liquid level transmitter, if not metal containers, you need to put the transmitter of the shell with a wire access the bottom of the container, otherwise not accurate measurement.

This product in the factory has a calibration, if need on-site adjustment can adopt the following methods:

1, using intelligent circuit debugging methods:

The zero -- -- -- -- -- - when the liquid level position is low, at the same time hold down the "Z" key and "S" key 8 seconds after release at the same time, then "Z" key press, the output current automatically adjusts to 4 ma.

Field adjustable full -- -- -- -- -- - when the liquid level high, at the same time hold down the "Z" key and "S" key 8 seconds after release at the same time, then the "S" key press, automatic adjustment to 20 ma output current.

2, USES the method of analog circuit debugging:

When the liquid level in the next period, use the screwdriver slowly rotating "Z" potentiometer, observe the ammeter reading close to 4 ma.

When the liquid level in the limited time, use a screwdriver slow rotation "S" potentiometer, observe 20 ma current meter reading is close.

So above 2 to 3 times repeatedly, until zero and range are accurate 20 ma ma and 4, respectively.

After adjust, should tighten the lid of the transmitter.

Eight, note:

1, who supply products with instruction manual and the certificate of approval, including product number, technical parameters, production date, etc., please check carefully, lest use wrong.

2, connect the power supply shall be in strict accordance with my company connection wiring instructions.

Found in 3, the use of exception, should turn off the power and stop using, check, or directly to our technical department.

4 should be restored the original packaging, transportation, storage, stored in a cool, dry and ventilated warehouse.

Nine, selection of code:

spectrum

instructions

ZW-DB40


In the static pressure type level gauge (wei measurement and control)

category

1


The cabling

2


Lever (sensor installed at the bottom, direct contact with the liquid medium)

3


The anti-corrosion type

4


Guide pressure lever (sensors mounted on the upper, not direct contact with the medium)

Process connection form

T


Bracket installation

N


Flange installationDN40 PN1.0

K


Clamp connection

Y


Specifically agreed

Sensor connection material

1


304

lever

2


316

3


316L

4


Nitrile butadiene rubber and PVC compounds

The cabling

5


Ptfe, flange (pp)

Explosion-proof way

O


Don't riot

E


Safety explosion-proofExia ⅡCT6

Display mode

O


Without the instructions

Z


With current meter instructions (0-100%Scale)

X


A live show

A counterweight

O


Without the weight

W


Need to weight


-□


The installation height (mm)


-□


Measure the height (mm)


-□

Density (measured mediumg/cm3)

Ten, design selection and ordering information:

1, specifications: ZW - DB400 series static pressure type level gauge;

2, the name of the measured medium, medium density;

3, measurement range, can also be referred to as the nominal length;

4, work pressure, work under pressure;

5, working temperature: measuring the temperature of the liquid;

6, material requirements: liquid material;

7, whether matching supply flange, bolts, nuts, valves, fittings, such as sealing washer;

8, flange standard: nominal size of the flange, 3/4 ", DN25, (, DN80, DN100, etc;

9, special requirements: before ordering, please indicate in detail.

Nine, after-sales service commitment:

1, our company sold by liquid level transmitter series products within twelve months appear quality problem, is responsible for free maintenance.

2, the warranty period, any quality problems such as the products of our company, my company is responsible for free repair or replacement.

3, the warranty period, such as user improper use, damaged products, my company is responsible for the maintenance, charge damage parts cost.

4, after the warranty period appear quality problem, my company is responsible for the maintenance, charge damage parts cost.

5, such as user need to my company site services, to users in the province I company service personnel to reach the site within 12 hours, fujian association of foreign languages and user reach the site within 48 hours.


Browse:
Return To The Top

分享到:

主站蜘蛛池模板: 国语国产操逼伊人AV网 | 人人免费成人亚洲10天的爱人在线观 | 国产JJIZZ女人老师多水免费 | 亚洲vV秘 码国产欧美成 | 好硬~好爽~别进去~嗯视频 | 久久综合结合久久很很很97色 | 国产精品无码毛片 | 91无限看丝瓜苏州晶体公司肌肌免费下载 | 蜜臀久久精品久久久久宅男 | 91制片厂制作果冻传媒八夷类似 | 免费精品视频91啪国 | 91制片厂制作传媒网 | 成人v影视一区二区三区 | 久青草国产视频 | 在线观看91精品国产不卡免费 | 成人一区二区三区高清 | 欧美在线精品一区 | 人人摸人人摸人干 | 欧美大片 | 午夜刺激黄瓜西瓜葡萄 | 欧美成人小说网址 | 亚洲bav在线观看 | 乱色精品无码一区二区国产盗 | 亚洲AV午夜精品无码专区一区 | xxx18日本护士 | 成人国产极品在线视频 | 91成人试看福利体验区 | 日韩无砖专区一中文字目码在线视频最新 | 国产挤奶| 亚洲国产成 | 中国精品久久久 | 在线观看午夜天堂 | 在线亚洲成人软件区 | 日本丰满妇人成熟免费中文字幕 | 在线欧美日韩 | 久久国产AVjust麻豆 | 久久人妻网 | 少妇被粗大的猛进出69影院软件 | 特级a欧美做爰片第一次 | 操一操干一干 | 91制片厂果冻传媒天美 |