Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.

Double flange remote liquid level meter

24雙法蘭遠(yuǎn)傳液位計(jì).png
  • 24雙法蘭遠(yuǎn)傳液位計(jì).png
Double flange remote liquid level meter is a sixteen bit chip, its powerful function and high speed …

Description:

Productoverview:

ZW3051LDP series Double flange remote liquid level meter Mainly used for measuring the following occasions: precipitation medium strong corrosive or toxic medium viscous medium under high temperature and crystallization of the medium with solid particles or suspended solids can eliminate the pipe leakage phenomenon: the pollution of the environment to be isolated by liquid, because the measurement signal is not stable, often need tedious work supplementary isolation liquid. A continuous measurement of the interface and density of remote device can avoid different instant mixing medium, the actual situation which makes the measurement results reflect the process of change.

Two, work principle:

ZW3051LDP series <strong> double flange remote liquid level gauge</strong> principle is when the measured medium pressure into two kinds of high and low pressure chamber two, role in the delta element (i.e. sensitive element) on both sides of the diaphragm, the spacer and components inside the filling liquid transferred to the measuring diaphragm on both sides. The liquid level transmitter is measured by the diaphragm and the both sides of insulation on the electrode sheet of each component of a capacitor. When the pressure is inconsistent, resulting in measuring diaphragm displacement, the displacement and the pressure difference is proportional to the capacitance on both sides from it, through stages of oscillation and demodulation, signal into proportional to pressure.

When the pressure gauge is connected to one end of the liquid phase, the other end of the air phase, according to the principle of fluid statics, have:

PB=PA+H p g (2-1)

Type: H - liquid height;

P - measured medium density;

By type (2-1) available:

P= PB PA= H p g

In general, the measured density and acceleration of gravity medium are known, therefore, the differential pressure gauge differential pressure and liquid measured the height of the H is proportional to the height of the problem of measuring the liquid into the differential pressure measurement.

Third, application:

ZW3051LDP series <strong> double flange remote liquid level gauge</strong> is used to prevent the pipeline media directly into the transmitter in the sensor module, and it is filled with fluid between the transmitter by capillary connected. For the measurement of liquid, gas or steam liquid level, flow and pressure, and then turn it into 4 ~ 20mA DC signal output.

Four, main features:

1, super performance measurement, for pressure, differential pressure, liquid level, flow measurement;

2, digital accuracy: + (- 0.05%);

3, accuracy: + (-) 0.75%+ (-) 0.1%F.S;

4, full performance: + (-) 0.25F.S;

5, the stability: 0.25% to 60 months;

6, range: 100:1;

7, volume rate: 0.2S;

8, small (2.4kg) stainless steel flange, easy to install;

9, the process of connecting the compatibility with other products, to achieve the ideal measurement;

10, sensor using H alloy sheath (Technology), achieved excellent cold and thermal stability;

11, using 16 bit computer intelligent transmitter;

12, the standard of 4-20mA, a digital signal based on HART protocol, remote control;

13, support to the field bus and based on field control technology upgrades;

Five, technical parameters:

Output signal: 4 ~ 20MA.DC two-wire (Analog)

Two line 4 ~ 20mA DC superimposed on the signal digital signal, linear or square output selected by the user.(intelligence);

Power supply: 12 ~ 45V.DC;

Effect: <0.005% power output range /V;

14, to provide a reliable measurement method to avoid the isolation diaphragm contact the measured medium directly to the transmitter;

Damping: usually in 0.1 to 16 seconds between the adjustable, when filling liquid with inert or remote transmission device, the time constant will increase;

Start time: <2 seconds, without preheating;

Work environment: the environment temperature of -29 to 93 DEG C (analog amplifier);

-29 ~ 75 C (digital / intelligent amplifier);

-29 to 65 DEG C (with display gauge);

Environmental humidity is 0 ~ 95%;

Protective properties: protective ability of IP65;

Explosion-proof type: flameproof type Exd II BT4-6;

This type of Exia II CT5;

The static effect of zero error: + 0.5%zui large range limit value for 32MPa in the pipeline under pressure by zero corrected;

The effects of electromagnetic radiation: 0.05%zui large range value, the radiation frequency is 27 ~ 500MHz, the test field 3V/m;

Indicator (%): LCD digital display precision + 0.2%;

Effect of vibration: vibration direction of any 200Hz, 0.05%/g;

Installation position: the diaphragm is not installed vertically, may produce less than 0.24KPa by adjusting the zero error, but zero correction;

Weight: 3.9Kg (not including attachments).

The six level, with the remote device is applicable to the following conditions:

1, to medium and high temperature transmitter isolation.

2, medium have a corrosive effect on transmitter sensitive element.

3, the measured medium due to environmental temperature changes or solidification or crystallization.

4, the replacement of the measured medium requires strict purification of measuring head.

5, the suspended liquid or high viscosity medium.

6, the measuring head must be kept clean and tidy.

7, the sealing pressure measuring container.

Seven, attention matters and daily maintenance:

1, the use of new double flange differential pressure transmitter, to inspect the diaphragm liquid filled the adequacy (how many businesses on the production requirements of electrode liquid filled different) such as too little, need to return to factory maintenance.

2, there is no solution in diaphragm and a long stem on sensor before use to check whether there is damage in need, the purpose is to make the pressure sensor, diaphragm rupture caused by oil mixed with measuring medium.

The use of protective sleeve should be 3, daily use of flange disassembly when not in use, should not be exposed outside the diaphragm.

4, can not long dry, often use Zui well preserved in the electrode protection solution, but to soak activated before use.

5, measurement of acid alkali will reduce the electrode life greatly, so as to frequent measurement of acid alkali Zui to buy special strong acid and alkali resistant diaphragm.

6, cleaning the membrane rinse water should not be too large, do not use scrub brush iron or other metals.

7, flange tohandlegentlyand, diaphragm is very fragile, so as to avoid collision.

Eight, the selection of encoding:

ZW3051LDP

Double flange remote differential pressure level meter  (Zhongwei control)


Code

Range KPa

Three

0-1.3 ~ Seven point five

Four

0-6.2 ~ Thirty-seven point four

Five

0-31.1 ~ One hundred and eighty-six point eight

Six

0-117 ~ Six hundred and ninety

Seven

0-345 ~ Two thousand and sixty-eight

Eight

0-117 ~ Six hundred and ninety


Code

output

E

4-20mADC

S

Intelligent type


Code

Flange material

Flange material

Twenty-two

316SST

316SST


Code

Additional function

S1

A remote transmission device


S2

A remote transmission device



Code

option

M1

0-100% Linear indicator

M2

LED Show table

M3

LCD Show table

B1

Tube bracket

B2

Plate bracket

B3

Tube plain bracket

D

Flameproof D IIBT4

I

Intrinsically safeIaCT6

Note:

In 1, the flange specifications selected working pressure on.

2, remote device operating temperature, liquid filling type is determined by the choice of irrigation.

3, remote differential pressure transmitter refers to the remote device on one side by the temperature effect caused by the variation of output.

4, static pressure and temperature, were measured at the maximal range.

5, remote differential pressure type liquid level meter side capillary length is generally 1.5 meters, not more than 3 meters (special agreement).

Nine, design selection and ordering information:

1, according to the selection of transmitter type specifications are determined according to the requirement.

2, the selection of specifications of the figures in the table, the symbol should be clear and accurate.

3, if there is a positive and negative transfer, must indicate the amount of numerical migration.

4, such as the differential pressure transmitter to be equipped with three valves, please note.

5, choose the remote transmitter, should also be based on different selection table to determine the transmission flange.

6, if the remote transmitter to be used in vacuum and high temperature occasion occasion, please note.

7, contact medium O ring material of rubber and fluorine rubber etc..

8, no special note, when the factory filled liquid silicone oil.

Customer service service commitment:

1, our level of quality products within twelve months, responsible for free maintenance.

2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.

3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.

4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.

5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.


Browse:
Return To The Top

分享到:

主站蜘蛛池模板: 成人午夜性a一 | 无码人妻精品一区二区三区啪啪 | 日屄视频在线播放 | 亚洲精品在线91 | 日韩伦理一区二区三区 | 国产日韩网 | 又色又爽又黄的视频网站 | 午夜性生活视频全免费 | 日韩欧美精品一区二区三区 | 日韩欧美国产aⅴ另类 | 亚洲欧美在线第一 | 午夜激情国产欧美一区 | 日韩国产综合在线 | 一二三国产乱伦小视频 | 熟女视频综合 | 久久er蜜桃 | 亚洲午夜一区二区三区在线观看 | 国产白白视 | 黑人玩弄 | 免费国产亚洲香蕉线 | 国产精品自拍一区 | 久青视频在线 | 97视频免费日韩电影在线观看 | 日韩v片 | 中文字幕在线永久视频 | 91在线午夜福利精品 | av一区二区在线观看萝 | 国产主播99 | 日本日B视频 | 日韩欧美偷拍 | 丁香五月丁香五月 | 中字无码视频一区.二区.三区 | A片区免费 | 无码精品人妻一区二区三区免费 | 国产精品乱码一 | 人人影视网全球独家播放影院网 | 日韩国产一区二区三区在线观看 | 午夜免费观看福利片 | 日本特黄特 | 国产迷奸在线 | 蜜桃一区二区三区在线 |